Description
Technical Parameters
Pressure range | -0.1~0~0.1MPa ; 0-40MPa |
Overload | 150%FS |
Comprehensive accuracy | 0.5%FS ; 1%FS |
Long term stability | ±0.2%FS/year |
Non-linearity | 0.2%FS |
Repeatability | 0.2%FS |
Singal output | 4‐20mA ; 0‐5V ; 0‐10V ; RS485 |
Power supply | 24(12~36V)DC |
Storage temperature | ‐40~85℃ |
Operating temperature | ‐20~85℃ |
Compensation temperature | ‐10~80℃ |
On-site display | LCD digital display |
Wetted material | SS316L ; PTFE ; 2205(customizable) |
Housing material | Flameproof Aluminum housing ‐2088 |
Protection grade | IP67 |
Electrical Connection | Ex-proof metal gland ; M20*1.5 Ex-proof gland (external) ; M20*1.5 Ex-proof gland (internal) ; 1/2NPT Ex-proof gland (external) ; 1/2NPT Ex-proof gland (internal) ; G1/2Ex-proof gland (external) ; G1/2 Ex-proof gland (internal) ; M20*1.5 plastic gland |
Process connection | G1/4 ; G1/2 ; 1/2NPT ; 1/4NPT ; M20*1.5, etc. |
Features
1.Strong corrosion resistance
2. Flameproof aluminum alloy housing,with LCD screen display
3. Wide range temperature compensation, good linearity
4. Reverse polarity protection, instantaneous overcurrent, overvoltage and anti-interference protection measures
Application
1. Oil and gas industry
2. Chemical and petrochemical industry
3. Energy and power industry
4. Urban gas system
5. Coal industry
6. Other working environments with dust/gas explosion risk